This is NKS NKS-R NKS-B News Seminars NKS Reports Phantom Library

You are here: Homepage NKS Reports View document

List all reports List all NKS-R reports List all NKS-B reports Search Reports  
NKS Programme Area:NKS-R
Research Area:Thermo hydraulics
Report Number:NKS-234
Report Title:PPOOLEX Experiments with Two Parallel Blowdown Pipes
Activity Acronym:POOL
Authors:Jani Laine, Markku Puustinen, Antti Räsänen
Abstract:This report summarizes the results of the experiments with two transparent blowdown pipes carried out with the scaled down PPOOLEX test facility designed and constructed at Lappeenranta University of Technology. Steam was blown into the dry well compartment and from there through either one or two vertical transparent blowdown pipes to the condensation pool. Five experiments with one pipe and six with two parallel pipes were carried out. The main purpose of the experiments was to study loads caused by chugging (rapid condensation) while steam is discharged into the condensation pool filled with sub-cooled water. The PPOOLEX test facility is a closed stainless steel vessel divided into two compartments, dry well and wet well. In the experiments the initial temperature of the condensation pool water varied from 12 ºC to 55 ºC, the steam flow rate from 40 g/s to 1 300 g/s and the temperature of incoming steam from 120 ºC to 185 ºC. In the experiments with only one transparent blowdown pipe chugging phenomenon didn’t occur as intensified as in the preceding experiments carried out with a DN200 stainless steel pipe. With the steel blowdown pipe even 10 times higher pressure pulses were registered inside the pipe. Meanwhile, loads registered in the pool didn’t indicate significant differences between the steel and polycarbonate pipe experiments. In the experiments with two transparent blowdown pipes, the steam-water interface moved almost synchronously up and down inside both pipes. Chugging was stronger than in the one pipe experiments and even two times higher loads were measured inside the pipes. The loads at the blowdown pipe outlet were approximately the same as in the one pipe cases. Other registered loads around the pool were about 50–100 % higher than with one pipe. The experiments with two parallel blowdown pipes gave contradictory results compared to the earlier studies dealing with chugging loads in case of multiple pipes. Contributing factors to this may be the smaller dry well volume per blowdown pipe ratio and the lack of dry well internal structures in the PPOOLEX facility. Furthermore, the pipe material seemed to have an effect on the condensation process inside the pipe. Polycarbonate has two orders of magnitude smaller thermal conductivity than steel.
Keywords:Condensation pool; steam/air blowdown; chugging; parallel blowdown pipes
Publication date:01 Jan 2011
ISBN:ISBN 978-87-7893-306-5
Number of downloads:2045
Download:pdf NKS-234.pdf
Contact NKS   NKS Sekretariatet
Boks 49
DK-4000 Roskilde
  Telephone +45 46 77 40 41
E-mail: nks@nks.org 
 

Address for visitors
Directions and map

Privacy policy

Cookie policy

 

Website last modified: 29 October 2024