This is NKS NKS-R NKS-B News Seminars NKS Reports Phantom Library

You are here: Homepage NKS Reports View document

List all reports List all NKS-R reports List all NKS-B reports Search Reports  
NKS Programme Area:NKS-R
Research Area:Thermo hydraulics
Report Number:NKS-198
Report Title:PPOOLEX Experiments on Thermal Stratification and Mixing
Activity Acronym:POOL
Authors:Markku Puustinen, Jani Laine, Antti Räsänen
Abstract:The results of the thermal stratification experiments in 2008 with the PPOOLEX test facility are presented. PPOOLEX is a closed vessel divided into two compartments, dry well and wet well. Extra temperature measurements for capturing different aspects of the investigated phenomena were added before the experiments. The main purpose of the experiment series was to generate verification data for evaluating the capability of GOTHIC code to predict stratification and mixing phenomena. Altogether six experiments were carried out. Heat-up periods of several thousand seconds by steam injection into the dry well compartment and from there into the wet well water pool were recorded. The initial water bulk temperature was 20 °C. Cooling periods of several days were included in three experiments. A large difference between the pool bottom and top layer temperature was measured when small steam flow rates were used. With higher flow rates the mixing effect of steam discharge delayed the start of stratification until the pool bulk temperature exceeded 50 °C. The stratification process was also different in these two cases. With a small flow rate stratification was observed only above and just below the blowdown pipe outlet elevation. With a higher flow rate over a 30 °C temperature difference between the pool bottom and pipe outlet elevation was measured. Elevations above the pipe outlet indicated almost linear rise until the end of steam discharge. During the cooling periods the measurements of the bottom third of the pool first had an increasing trend although there was no heat input from outside. This was due to thermal diffusion downwards from the higher elevations. Heat-up in the gas space of the wet well was quite strong, first due to compression by pressure build-up and then by heat conduction from the hot dry well compartment via the intermediate floor and test vessel walls and by convection from the upper layers of the hot pool water. The gas space temperatures also stratified.
Keywords:Condensation pool; steam/air blowdown; thermal stratification
Publication date:01 Aug 2009
ISBN:ISBN: 978-87-7893-265-5
Number of downloads:1805
Download:pdf NKS-198.pdf
Contact NKS   NKS Sekretariatet
Boks 49
DK-4000 Roskilde
  Telephone +45 46 77 40 41
E-mail: nks@nks.org 
 

Address for visitors
Directions and map

Privacy policy

Cookie policy

 

Website last modified: 16 April 2024